Eldes ESIM264 Manual de usuario Pagina 7

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 16
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 6
USER MANUAL ELDES ESIM264 V1.0 7
EN
E.g. XXXX_INFO:0.2, means that status message will be sent every 2 hours.
To disable periodic status messages, send SMS:
The status message INFO will not be sent until enabling or restoring default parameters.
2.9 Remote Microphone listening
To be able to listen what is going on in remote house can be done in two dierent ways:
1. When alarm has been activated, the system will ring pre-programmed numbers and user can answer the call. Remote
microphone will be enabled for listening.
2. By sending SMS message
The system will ring the sender of former SMS, and upon answering the call, user can listen to any sounds in the building. The
phone call must be answered within 20 seconds otherwise the system will stop trying and return to previous state.
2.10 Receiving alarm message due to temperature deviation
The system ESIM264 informs the user by SMS message in the case if temperature deviation from the set values. In order to use
this function it is necessary to connect temperature sensor and set the parameters accordingly. Examples of usage: temperature
control for greenhouses, houses, aquariums, server premises, refrigerators etc. over a GSM network.
Manufacturer set this function o. To turn the system on send the following SMS message:
min – temperature in oC, it can have values [-55...+125] max – temperature in
o
C, can have values [-55...+125].
If the controlled temperature drops below min value by one degree, the user will receive SMS message with the temperature at
that time. If the controlled temperature rises above max value by one degree, the user will receive SMS message with the tempe-
rature at that time.
E.g. XXXX_TEMP:16:20 means that SMS message will be sent if the temperature drops below 16
o
C or rises above 20
o
C.
XXXX_TEMP:-10:-1 means that SMS message will be sent if the temperature drops bellows -10
o
C or rises above -1
o
C
To see temperature settings send the following SMS message:
To turn o temperature control, send the following SMS message:
If the value received by the system is two zeros, it will not react to temperature change. However, if the
sensor is connected, temperature information will be sent together with INFO message, as described
in section 2.8.
XXXX_INFO:00.00
XXXX_TEMP:min:max
XXXX_TEMP
XXXX_TEMP:0:0
1111 M:
OFF
1111 INFO
:0.2
XXXX_MIC
ESIM 264
1111 TEMP
:16:20