Zone Type
Entry Delay
Follow–thiszonedoesn'treacttoviolationsduringDelaytime.
Instant -whenthiszoneisviolated,immediatelycauseanalarm.
Delay -doesn'treacttoviolationsintimeperiodwhichisusedtoentersecuritypassword.
24H -thiszoneisactiveallthetime,evenwhenthesystemisdisarmed.
Fire-thistypeofzoneisusedtoconnectsmokedetectors.
Silent-thiszoneworksas24Hzoneandwhenitisviolated,thesystemdoesn'tturnon
the siren.
Thiseldisusedtocongurethetimewhichisdedicatedtodisarmthesecuritysystem
whenusersentersinthespeciedDelayzone.Ifsystemwillnotbedisarmedintime,theit
willcauseanalarm.Bydefault,thistimeis15seconds.Thisparametercanbeadjustedon
forDelaytypezones.
Enter code 52, zone number and function:
Follow-[53xx1#]
Instant-[53xx2#]
24H-[53xx3#]
Delay-[53xx4#]
Fire-[53xx5#]
Silent-[53xx6#]
where x – zone number. Parameter range from 01 to 44
EKB3
Enter code 54, zone number and function:
Zone1–[5401x#]
Zone2–[5402x#]
Zone3–[5403x#]
...
Zone44–[5444x#]
where x – time in seconds.