USER MANUAL EKB3 V1.0 5
4. Operation description
WhenthesystemisdisarmedandoperatingnormallyitwilldisplaygreenLEDcalledREADY.Whenanyzoneisviolated,thegreen
LEDcalledREADYturnsoandtheredLEDwiththenumberofviolatedzoneshowsup.Systemsoundsignalerusestwotypeof
signals-threeshortbeepsandonelongbeep.Threeshortbeepsstandsforsuccessfulcompletetasksandonelongbeepstandsfor
unsuccessfulcompletetasks.Star(*)buttonstandsforcancel.
4.1 Arming-Disarming the system
Toarmthesecuritysystemuserhavetoenteravalidkeyboardpassword.Thesystemstartstocountthetimededicatedtoleavethe
premises.Theuserisinformedaboutthetimecountdownbyasoundsignal.Whensystemissuccessfularmed,theredLEDcalled
ARMEDdisplays.
Todisarmthesecuritysystemuserhavetoenteravalidkeyboardpassword.Whenusersentersintosecuredpremises,thesystem
startstocountthetimededicatedtoenterkeyboardpassword.Ifuserswillnoenteravalidkeyboardpassword–thesystemwillcause
analarm.Whensystemissuccessfuldisarmed,theredLEDcalledARMEDturnso.
4.2 System troubles
YellowLED called SYSTEM indicatessystemtroubles.Tocheckthespecictroubleuse command [CODE#],where CODEmeansa
buttonnamedCODE.Thesystemfor15secondsshowstroubleswithzonesredLEDindicators.Thespecictroublesaredisplayedin
the table below.
Zone number Trouble
1 Tamper
2 Backupbattery
3 Mainpower
4 Time
5 Highzones*
6 GSMconnection
*Highzonesaretroubledzonesabove12.
IfyellowLEDcalledSYSTEMisblinkingmeansthatthereareviolatedzonesortampersabove12.Tocheckwhichzoneisviolateduse
command[CODE1],whereCODEmeansabuttonnamedCODE.Tocheckwhichtamperisviolatedusecommand[CODE2],where
CODEmeansabuttonnamedCODE.Thekeyboardwilldisplayacodeofviolatedzone.Toknowwhichzoneortamperabove12is
violated,useaformulaB+A,e.g.ifsystemdisplayszones5and10,meansthatviolatedzoneis30+5=35.
A B
Zonenumber1=1 Zonenumber7=12
Zonenumber2=2 Zonenumber8=18
Zonenumber3=3 Zonenumber9=24
Zonenumber4=4 Zonenumber10=30
Zonenumber5=5 Zonenumber11=36
Zonenumber6=6 Zonenumber12=42
4.3 Bypassing zones
Tobypassanyzoneusethecommand[BYPSxxyyyy#],whereBYPS-meansabuttonnamedBYPS,xx–zonenumberandyyyy–key-
boardpassword.Usethesamecommandtoenablebypassedzones.Thezonecanbebypassedonlyfortemporaryperiodandafter
arming-disarmingthesystemitwillbeactiveagain.
4.3 Conguration commands
Tousecongurationcommandsuserhavetoenteradministratorcode.Administratorcodecanbeenteredtothesystemwithcom-
mand[*XXXX#],whereXXXX–administratorcode.WhenadministratorcodeisenteredsuccessfullytheredLEDcalledARMEDstarts
blinking.