20
Temperature
Limit Info SMS
Alarm time
Info SMS scheduler
Whenthisfunctionisenabled,systemsendstheinformationbySMSmessagesabouttempe-
raturedeviationfromthesetvalues.Bydefault,thisfunctionisenabled.
Thisparameterisusedforsettingthetimeofdevicealarmsirensoundafterthealarmisacti-
vated.Thetimeisindicatedinminutes.Factorydefaultsetting–1minute.Parameterrange
from00to10.
ThesystemESIM264periodicallysendsinformationmessagesaboutdevicestatus.Theuser
canspecifythefrequencyandtimeofthesecontinuousmessages.Time–speciesthetime
atwhichinformationmessagewillbedelivered.Parameterrangefrom01to23.Period–spe-
ciesafterhowmanydaysrepetitiveinformationmessagesaredelivered.Parameterrange
from01to255.
Enter code 50 and function:
Disabled–[500#]
Enabled-[501#]
Enter code 10 and count of minutes:
[10xx#]
where xx – minutes.
Enter code 11, time and period:
[11xxyy#]
where xx – time, yy – period .
EKB3
EKB3
EKB3
4.3.6 Other commands