Manual ElDES ESIM264 v2.2 11
2. Technical Specications
2.1 Electrical & Mechanical Characteristics
Electrical & Mechanical Characteristics
Main Power Supply 16-24V 50 Hz ~1.5A max / 18-24V 1,5A max
Current in Standby without External Sensors and Keyboard Up to 80mA
Recommended Backup Battery Voltage, Capacity 12V; 1,3-7Ah
Recommended Backup Battery Type Lead-Acid
Maximum Battery Charge Current 900mA
GSM Modem Frequency 850/900/1800/1900MHz
Cable Type for GSM Antenna Connection Shielded
Number of Zones on Board 6 (ATZ mode: 12)
Nominal Zone Resistance 5,6k (ATZ Mode: 5,6k and 3,3k)
Number of PGM Outputs on Board 4
PGM Output C1-C4 Circuit
Maximum Commuting PGM Output Values Voltage – 30V; Current – 100mA;
BELL: Siren Output when Activated Connected to COM
BELL: Maximum Siren Output Current 500mA
BELL: Maximum Cable Length for Siren Connection up to 30 meters
BELL: Cable Type for Siren Connection Unshielded
AUX: Auxiliary Equipment Power Supply Voltage 13,8V DC
AUX/BELL: Maximum Accumulative Current of Auxiliary Equip-
ment and Siren
1A
AUX: Maximum Cable Length for Auxiliary Equipment Connection up to 100 meters
AUX: Cable Type for Auxiliary Equipment Connection Unshielded
BUZ: Maximum Current of Mini Buzzer 150mA
BUZ: Power Supply Voltage of Mini Buzzer 5V DC
BUZ: Cable Type for Mini Buzzer Connection Unshielded
Dimensions 140x100x18mm
Operating Temperature Range -20...+55
0
C
Supported Temperature Sensor Model Maxim®/Dallas® DS18S20, DS18B20
DATA: Maximum Cable Length for 1-Wire® Communication up to 30 meters
DATA: Cable Type for 1-Wire® Communication Unshielded
Supported iButton® Key Model Maxim®/Dallas® DS1990A
Maximum Supported Number of Keyboards 4 x EKB2 / EKB3
Y/G: Maximum Cable Length for RS485 Communication up to 100 meters
Y/G: Cable Type for RS485 Communication Unshielded
MIC: Maximum Cable Length for Microphone Connection Up to 2 meters
MIC: Cable Type for Microphone Connection Unshielded
Wireless Transmitter-Receiver Frequency * 868 Mhz
Wireless Communication Range* Up to 30m in premises; up to 150m in open areas
Maximum Supported Number of Wireless Devices* 16
Event Log Size 500 events
Maximum Supported Number of Zones 44
Maximum Supported Number of PGM Outputs 44
Cable Type for Zone and PGM Output Connection Unshielded
Communications SMS, Voice calls. GPRS network, RS485, CSD
Supported Protocols Ademco Contact ID®, 4+2, EGR100, Kronos
* only for system ESIM264 with module EWT1
1 R
OUT
Open Collector Output.
Output is pulled to COM
when turned ON.
Comentarios a estos manuales