Eldes ESIM264 Manual de instalación Pagina 9

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 140
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 8
Manual ElDES ESIM264 v2.2 9
1.3 Default Parameters & Ways of Parameter Conguration
Main Parameters
Parameter Default Value
Congurable by:
SMS EKB2 EKB3 Conguration Tool
SMS & EKB2 Menu Language Depends on rmware version according to user‘s location
SMS Password 0000
User Password 1 1111
User Password 2... 10 N/A
Administrator Password 1470
Duress Password N/A
SGS Password N/A
User 1... 5 Phone Number N/A
Allow Control from Any Phone Number Disabled
Remote Listening when Calling Disabled
Date & Time N/A
Zones
Parameter Default Value
Congurable by:
SMS EKB2 EKB3 Conguration Tool
Zone Alarm Text
Z1 - Door sensor triggered, Z2 - Windows sensor triggered, Z3 - Fire sensor
triggered, Z4 - Motion1 sensor triggered, Z5 - Motion2 sensor triggered,
Z6 - Motion3 sensor triggered etc.
Entry Delay 15 seconds
On-Board Zone Delay 800 milliseconds
EPGM1 Zone Delay 800 milliseconds
On-board Z1 Zone Type Delay
Exit Delay 15 seconds
On-board Z2... Z12 Zone Type Instant
Keyboard Zone Type Instant
EPGM1 Zone Type Instant
Wireless Zone Type Depends on the connected wireless device
Virtual Zone Type Follow
ATZ Mode Disabled
Zone Connection Type when ATZ Mode Dis
-
abled
Type 1
Zone Connection Type when ATZ Mode En
-
abled
Type 4
On-board Zone Status Enabled
Keyboard Zone Status Disabled
EPGM1 Zone Status Enabled
Wireless Zone Status Enabled
Virtual Zone Status Disabled
Stay Mode for Particular Zone Disabled
Arm-Disarm by Zone N/A
Force Mode for Particular Zone Disabled
Tamper Name Tamper 1, Tamper 2, Tamper 3, Tamper 4, Tamper 5, Tamper 6 etc.
Chime Enabled
PGM Outputs
Parameter Default Value
Congurable by:
SMS EKB2 EKB3 Conguration Tool
PGM Output Name C1 – Controll1, C2 – Controll2, C3 – Controll3, C4 – Controll4 etc.
PGM Output Status Disabled
EPGM8 PGM Output Status Disabled
EPGM1 PGM Output Status Disabled
Wireless PGM Output Status Enabled
Wireless PGM Output Type Depends on the connected wireless device
PGM Output Control by Event 1... 16 Disabled
PGM Output Control by Event Management N/A
Scheduler 1... 16 Disabled
Turn ON/OFF PGM Output by Timer N/A
Using Module EPGM8 Mode Disabled
Siren
Parameter Default Value
Congurable by:
SMS EKB2 EKB3 Conguration Tool
Siren Alarm Duration 1 minute
Bell Squawk Disabled
Activate Siren if Wireless Device is Lost Disabled