34
SMS
N/A
EKB2
Menu path:
OK → CONFIGURATION → ZONES → ARM/DISARM BY ZONE → ZONE [1... 12]
EKB3
Enter parameter 34 & zone number :
[34xx#]
Value: xx – zone number, range – [01... 12]
SMS
N/A
EKB2
Menu path:
OK → CONFIGURATION → ZONES → ARM/DISARM BY ZONE → N/A
EKB3
Enter parameter 34 & parameter status value :
[3400#]
This feature allows to set a zone for arming and disarming the alarm system when the zone
gets violated and restored. Violating and restoring the zone leads to system arming and by
repeating this action the system becomes disarmed. This mode can be set for 1 on-board
zone only.
6-zone mode (ATZ mode disabled): a 5.6k resistor is required for the set zone.
ATZ mode: a 5.6k resistor is required for Z1-Z6 zones and additionally a 3.3k resistor is
required for Z7-Z12.
This command disables Arm-Disarm by Zone mode.
Enable Arm-
Disarm by Zone
Disable Arm-
Disarm by Zone
See also chapter 2.3.2 Zone Connection Types