134
SMS
N/A
EKB2
Menu path:
OK CONFIGURATION ARC SET COMMUNICATION DEVICE ID [XXXX]
Value: [XXXX] – 4-digit ID number, range – [0000... 9999]
EKB3
Enter parameter 47 & unit ID number:
[47xxxx#]
Value: xxxx – 4-digit ID number, range – [0000... 9999]
The 4-digit ID number of the alarm system intended for system identication by EGR100
softwa re.
This parameter can be set and edited using ELDES Conguration Tool and SMS only.
Set Unit ID
SMS
N/A
EKB2
Menu path:
OK CONFIGURATION ARC SET COMMUNICATION GPRS ATTEMPTS [XXX]
Value: [XXX] – number of GPRS attempts, range – [0... 255]
EKB3
Enter parameter 68 & number of GPRS attempts:
[68xxx#]
Value: xxx – number of GPRS attempts, range – [0... 255]
This command sets the number of data transmission attempts via GPRS network in case the
initial attempt was unsuccessful. Default value is 3.