9. Monitoring Station
9.1 Basic Overview
The data transmission from ESIM264 alarm system to monitoring station can be carried out by one of the following communication
methods at a time:
GPRS Network (EGR100/Kronos software protocol)
Voice Calls (Ademco Contact ID®, 4+2 protocol);
RS485;
CSD (fax line).
The system supports 1 primary connection and up to 3 backup connections. All of the aforementioned communication methods can
be set up as primary or backup in any sequence order by EKB2 keyboard, EKB3 keyboard and ELDES Conguration Tool software. For
more details, please, refer to softwares HELP section and chapter 9.3 Monitoring Station Parameter Conguration (SMS, EKB2,
EKB3).
ATTENTION: ESIM264 system is fully compatible with Kronos NET/Kronos LT monitoring station software for communication via
GPRS network. When using dierent monitoring station software, EGR100 GPRS software is necessary. EGR100 is freeware and can
be downloaded at www.eldes.lt
9.2 Data Messages
The conguration of data messages transmitted to the monitoring station is based on Ademco Contact ID®, protocol. The data mes-
sages can either be transmitted to the monitoring station alone or with duplication by SMS messages to User 1 phone number.
The following table provides a list of events supported by ESIM264 alarm system:
Seq. No. Contact ID® Code Description Duplication by SMS
1 1110 Fire Zone Alarm
*
2 3111 Fire Zone Restore
3 1121 Disarmed by User (Duress Password)
**
4 3121 Armed by User (Duress Password)
**
5 1130 Burglary Alarm
*
6 3130 Burglary Restore
7 1133 24H Zone Alarm
*
8 3133 24H Zone Restore
9 1144 Tamper Alarm
10 3144 Tamper Restore
11 1146 Silent Zone Alarm
*
12 3146 Silent Zone Restore
13 1158 Temperature Exceeded
14 1159 Temperature Fallen
15 1301 Main Power Loss
16 3301 Main Power Restore
17 1302 Wireless Sensor Low Battery
18 1308 Device Shut Down
19 1311 ESIM264 Backup Battery Fail
20 1381 Wireless Signal Loss
***
21 3381 Wireless Signal Restore
22 1401 Disarmed by User
23 3401 Armed by User
24 1456 Disarmed by User (Stay Mode)
**
25 3456 Armed by User (Stay Mode)
**
26 1463 Disarmed by User (SGS Password)
**
27 3463 Armed by User (SGS Password)
**
28 1602 Periodical Test
29 1900 Device Started