Menu path:
OK CONFIGURATION ZONES ZONE MODE NO ATZ TYPE [1... 3]
EKB3
Enter parameter 38 & zone mode:
[381#] - Type 1
[382#] - Type 2
[383#] - Type 3
SMS
N/A
EKB2
Menu path:
OK CONFIGURATION ZONES ZONE MODE ATZ TYPE [4... 5]
EKB3
Enter parameter 39 & zone mode:
[391#] - Type 4
[392#] - Type 5
Set zone connection type for 6-zone mode (when ATZ mode is disabled). Available types:
Type 1 – Normally open (NO) contact with 5,6K end-of-line resistor.
Type 2 – Normally closed (NC) contact with 5,6K end-of-line resistor
Type 3Tamper and 5,6K end-of-line resistor and 3,3K end-of-line resistor with normally
closed (NC) contact
Set zone connection type when ATZ mode is enabled. Available types:
Type 4 – 5,6K end-of-line resistor and normally closed (NC) contact with 3,3K end-of-line
resistor and normally closed (NC) contact.
Type 5Tamper and 5,6K end-of-line resistor and 5,6K end-of-line resistor with normally
closed (NC) contact and 3,3K end-of-line resistor with normally closed (NC) contact.
Set Zone Connection
Type when ATZ
Mode Disabled
Set Zone Connection
Type when ATZ
Mode Enabled
See also chapter 2.3.2 Zone Connection Types.