Manual ElDES ESIM264 v2.2 41
SMS
N/A
EKB2
Menu path:
OK → CONFIGURATION → ZONES →
WIRED ZONES → [ZONE 1... 12] → TYPE → FOLLOW / INSTANT / 24H / DELAY / FIRE / SILENT
OK → CONFIGURATION → ZONES → WIRELESS ZONES →
RF ZONE [1... 16] → TYPE → FOLLOW / INSTANT / 24H / DELAY / FIRE / SILENT
OK → CONFIGURATION → ZONES → KEYBOARD ZONES →
[1ST... 4TH] KEYBOARD ZONE → TYPE → FOLLOW / INSTANT / 24H / DELAY / FIRE / SILENT
OK → CONFIGURATION → ZONES → EPGM ZONES →
EPGM ZONE [1... 16] → TYPE → FOLLOW / INSTANT / 24H / DELAY / FIRE / SILENT
EKB3
Enter parameter 53, zone number & zone type index:
[53xx1#] - Follow
[53xx2#] - Instant
[53xx3#] - 24H
[53xx4#] - Delay
[53xx5#] - Fire
[53xx6#] - Silent
Value: xx – zone number, range – [01... 44]
Each zone can be set to operate under one of these types:
Follow – zone is inactive during Entry/Exit Delay countdown.
Instant – the alarm is caused instantly in case of zone violation.
24H – zone is always active, even when the system is disarmed.
Delay – inactive for a period of time dedicated to disarm the alarm system or leave the pre-
mises (Entry/Exit Delay).
Fire – this zone is intended for smoke detectors and is always active, even when the system
is disarmed.
Silent – operates in the same way as 24H type, but siren is not activated during zone violation.
Set Zone Type