42
SMS
N/A
EKB2
Menu path:
OK → CONFIGURATION → ZONES → WIRED ZONES → [ZONE 1... 12] → STAY → ENABLE
OK → CONFIGURATION → ZONES → WIRELESS ZONES
→ RF ZONE [1... 16] → STAY → ENABLE
OK → CONFIGURATION → ZONES → KEYBOARD ZONES
→ [1ST... 4TH] KEYBOARD ZONE → STAY → ENABLE
OK → CONFIGURATION → ZONES →
EPGM ZONES → EPGM ZONE [1... 16] → STAY → ENABLE
EKB3
Enter parameter 56, zone number & parameter status value:
[56xx1#]
Value: xx – zone number, range – [01... 44]
Stay mode enables the users to arm and disarm the alarm system while staying inside the se-
cured premises. The system goes into Stay mode in case the Delay zone is not violated during
the Exit Delay countdown (the user does not leave the secured area) and the zones which are
congured as Stay will not be secured. Stay mode is not activated if the user leaves the secu-
red premises during Exit Delay countdown or if none of the zones are congured to operate
under Stay mode. By default, this feature is disabled for all zones.
Enable Stay Mode
for a Specied Zone
NOTE: Stay mode becomes ineective if the user leaves the secured premises during Exit Delay countdown.