62
SMS
N/A
EKB2
Menu path:
OK → CONFIGURATION → PRIMARY SET →
POWER STATUS → AC RESTORE DELAY → [XXXXX]
Value: [XXXXX] – main power restore delay in seconds, range - [0... 65535]
EKB3
Enter parameter 71 & duration in seconds:
[71xxx#]
Value: xxx – main power restore delay in seconds, range - [0... 65535]
SMS
SMS text:
XXXX_MIC
Example: 1111_MIC
EKB2
N/A
EKB3
N/A
This command allows to set main power restore delay time period notifying all preset users
about main power supply restore events. If the power supply is lost again during restore de-
lay time period, the system will not notify the user (-s) about this event. Default value is 120
seconds.
This feature is useful when encountering temporary power supply failures.
This feature provides a possibility to listen to what is going on in the secured area where the
alarm system with connected microphone is installed. After sending the SMS message the
system calls back to the user and upon answering the call, user can listen to any sounds in the
building. The phone call must be answered within 20 seconds otherwise the system ends the
call and returns to previous state.
Alternative way 1: The system always makes a call to the user in case of alarm (unless this
feature is disabled).
Alternative way 2: The system answers the phone call from a preset user phone number (if
this feature is enabled). For more details on this feature, please, refer to ELDES Conguration
Tool software‘s HELP section.
Set Main Power
Restore Delay
Remote Listening
5.4.14 Remote Listening
ATTENTION: Remote listening feature becomes disabled when the system is connected to the monitoring station.
Comentarios a estos manuales