9.3.2 GPRS Network Settings
SMS
SMS text:
XXXX_SETGPRS:IP:0.0.0.0
Value: 0.0.0.0 – server IP address digits
Example: 1111_SETGPRS:IP:65.82.110.15
EKB2
Menu path:
OK CONFIGURATION ARC SET GPRS SETTINGS SERVER IP [0.0.0.0]
Value: [0.0.0.0] – server IP address digits
EKB3
Enter parameter 40 & Server IP address:
[40xxxxxxxxxxxx]
Value: xxxxxxxxxxxx – server IP address digits
Public IP address of the monitoring station. This parameter is intended for communication
between the alarm system and monitoring station via GPRS network.
Set Server IP Address
NOTE: 0 value disables test data message.
SMS
N/A
EKB2
Menu path:
OK CONFIGURATION ARC SET COMMUNICATION ATTEMPTS PERIOD [XXXXX]
Value: [XXXXX] – delay between attempts time period in seconds, range – [0...
65535]
EKB3
Enter parameter 69 & time period:
[69xxxxx#]
Value: xxxxx - delay between attempts time period in seconds, range – [0...
65535]
This feature allows to set a delay period of time before repeating the data message trans-
mission attempt to monitoring station by Primary connection in case all of the previous
attempts by all set connections were unsuccessful. Default value is 180 seconds. Recom-
mended value is 600 seconds.
Set Delay after Last
Communication
Attempt