Eldes EKB3 Manual de instalación Pagina 105

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 168
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 104
105
105EN
MANUAL ELDES ESIM264 V3.1
30.2.2. Voice Calls and SMS
The system supports up to 3 monitoring station phone numbers for communication with the alarm system by Voice Calls or SMS commu-
nication method. Tel. Number 1 is mandatory, the other two can be used as backup phone numbers and are not necessary. The supported
phone number format is the following:
International (w/o plus) – The phone numbers must be entered starting with an international country code in the following format:
[international code][area code][local number], example for UK: 4417091111111.
To set up the system for data transmission via Voice Calls or SMS, please follow the basic conguration steps:
1. Enable MS Mode parameter (see 30. MONITORING STATION).
2. Set 4-digit Account number (see 30. MONITORING STATION).
3. Set Tel. Number 1... 3.
Set monitoring station
phone number
EKB2
Menu path:
OK CONFIGURATION OK aaaa OK MS SETTINGS OK VOICE CALLS/SMS ST
OK TEL. NUMBER 1... 3 OK ttteeellnnuumm OK
Value: aaaa – 4-digit administrator password; ttteeellnnuumm – up to 15 digits monitoring
station phone number.
EKB3
Enter parameter 26, phone number slot & phone number:
26 ps ttteeellnnuumm #
Value: ps – phone number slot, range – [01... 03]; ttteeellnnuumm – up to 15 digits monito-
ring station phone number.
Example: 26014417091111111#
Cong
Tool
This operation may be carried out from the PC using the ELDES Conguration Tool software.
Delete monitoring
station phone number
EKB2
Menu path:
OK CONFIGURATION OK aaaa OK MS SETTINGS OK VOICE CALLS/SMS ST
OK TEL. NUMBER 1... 3 OK OK
Value: aaaa – 4-digit administrator password.
Cong
Tool
This operation may be carried out from the PC using the ELDES Conguration Tool software.
By default, if the initial attempt to transmit data to the monitoring station’s Tel Number 1 via Voice Calls or SMS method is unsuccessful, the
system will make up to 4 additional attempts. After all unsuccessful attempts, the system will continue to communicate with the monitor-
ing station by switching to the next phone number that follows in the sequence and making up to 4 additional attempts if the initial at-
tempt is unsuccessful. If all attempts to all phone numbers are unsuccessful, the system will switch to next backup connection that follows
in the sequence and will attempt to transmit data until it is successfully delivered to the monitoring station.
Set attempts
EKB2
Menu path:
OK CONFIGURATION OK aaaa OK MS SETTINGS OK VOICE CALLS/SMS ST
OK ATTEMPTS OK at OK
Value: aaaa – 4-digit administrator password; at – number of attempts, range – [1... 10].
EKB3
Enter parameter 37 & number of attempts:
37 at #
Value: at – number of attempts, range – [01... 10].
Example: 3706#
Cong
Tool
This operation may be carried out from the PC using the ELDES Conguration Tool software.