Eldes EKB3 Manual de instalación Pagina 120

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 168
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 119
120
120 EN
MANUAL ELDES ESIM264 V3.1
C2 C1
C1 Z1 Z2C2 COM COM Z3 Z4COM Z5 Z6COM Z7 Z8COM Z9 Z10COM Z11 Z12COM Z13 Z14COM Z15 Z16COM COM
-
AUX DC+ Y G+
Z1 Z2 Z3 Z4 Z5 Z6 Z7 Z8 Z9 Z10 Z11 Z12Z13 Z14 Z15Z16
STATUS
47
C2 C1
C1 Z1 Z2C2 COM COM Z3 Z4COM Z5 Z6COM Z7 Z8COM Z9 Z10COM Z11 Z12COM Z13 Z14COM Z15 Z16COM COM
-
AUX DC+ Y G+
Z1 Z2 Z3 Z4 Z5 Z6 Z7 Z8 Z9 Z10Z11 Z12Z13 Z14 Z15Z16
STATUS
Z1
Z2
RELAY
MODULE
EPGM1
Z3
Z4
Z5
Z6
Z7
Z8
Z9
Z10
Z11
Z12
Z13
Z14
Z15
Z16
5,6 kΩ
5,6 kΩ
5,6 kΩ
5,6 kΩ
5,6 kΩ
5,6 kΩ
5,6 kΩ
5,6 kΩ
5,6 kΩ
5,6 kΩ
5,6 kΩ
5,6 kΩ
5,6 kΩ
5,6 kΩ
5,6 kΩ
5,6 kΩ
Y
G
AUX-
AUX+
ESIM264
48
31.1.3.2. Installation
1. Disconnect ESIM264 alarm system main power supply and backup battery.
2. Connect EPGM1 DC+ terminal to ESIM264 AUX+ terminal, EPGM1 COM terminal to ESIM264 AUX- terminal, EPGM1 Y and G terminals
must be connected to ESIM264 Y and G terminals respectively (see Fig. No. 48).
3. Connect the resistors and sensors to EPGM1 module according to the selected zone connection Type 1, Type 2 or Type 3 (see 2.3.2
Zone Connection Types). If ATZ mode is enabled, please connect the resistors and sensors according to zone connection Type 1 or
Type 2.
4. Power up ESIM264 system.
5. Upon successful startup indicator STATUS should be blinking indicating successful EPGM1 operation.
6. EPGM1 is ready for use with ESIM264 alarm system.
NOTE: ATZ mode is not supported by EPGM1 zones.
NOTE: When ATZ mode is disabled, all EPGM1 zones must be wired in accordance with zone connection type set up in the system soft-
ware-wise i.e. Type 1, Type 2 or Type 3. If ATZ mode is enabled, EPGM1 zones can be wired in accordance with Type 1 or Type 2 only
(mixed combination of these two zone connection types is permitted), regardless of the set up zone connection type in the system.
For more details on multiple EPGM1 module wiring, please refer to 3.2.7. RS485