110 EN
MANUAL ELDES ESIM264 V3.1
Jumper position Address Jumper position Address
A0
A1
Keypad 1
A0
A1
Keypad 3
A0
A1
Keypad 2
A0
A1
Keypad 4
The address of each connected keypad is also indicated in ELDES Conguration Tool software.
31.1.1.2. Installation
1. Remove the screw located on the bottom side of the enclosure (see Fig. No.
40)
2. Detach keypad holder from EKB2 keypad by gently pulling the holder
towards yourself (see Fig. No. 41).
3. Fix the keypad holder on the wall using the screws. (see Fig. No. 42)
4. Disconnect ESIM264 main power supply and backup battery.
5. Wire up keypad terminals to ESIM264 alarm system respectively – Vin to
AUX+, COM to AUX-, Y to Y, G to G (see Fig. No. 43).
6. Connect a sensor and the resistor across Z1 and COM terminalss in accor-
dance with zone connection Type 1 or Type 2 (see 2.3.2. Zone Connec-
tion Types). As keypad zone Z1 is disabled by default, it can be enabled
by SMS, ELDES Conguration Tool, EKB2 and EKB3 keypad. Keypad zone Z1
must be enabled and resistor connected even if the tamper button alone is
required (see Fig. No. 43).
NOTE: Keypad zone connection type can dier from selected on-board
zone connection type.
NOTE: ATZ mode is NOT supported by keypad zones. ATZ mode is
ineective for keypad zones when enabled.
7. Set the keypad address by putting the jumper on A0 and A1 pins (see
32.1.1.1.4 Keypad Address).
8. Fix the keypad into the holder.
ATTENTION: Before xing the keypad into the holder please , make
sure that the tamper button is properly pressed (see Fig. No. 39).
9. Screw in the bottom side of the enclosure. (see Fig. No. 40).
10. Power up ESIM264 alarm system.
11. EKB2 keypad is ready.
For more details on multiple keypad wiring, please refer to 3.2.7. RS485