1. GENERAL INFORMATION
1.1. Functionality
ESIM264 – micro-controller based alarm system for houses, cottages, country homes, garages and other buildings, also capable of manag-
ing electrical appliances via cellular GSM/GPRS network. It can also be used as Intercom system.
Examples of using the system:
• Property security.
• Alarm switch.
• Thermostat, heating and air-conditioner control, temperature monitoring.
• Lighting, garden watering, water pump and other electrical equipment control via SMS text messages.
• Remote listening to what is happening in the secured area.
• Main 230V power status with SMS text message.
• Two-way intercom device via GSM network.
1.2. Compatible Device Overview
Wired Devices
Device Description Max. Connectable Devices
EKB2 LCD keypad 4*
EKB3 LED keypad 4*
EA1 Audio output module with 3,5mm jack 1**
EA2 Audio amplier module 1W 8 1**
EPGM1 16 zone and 2 PGM output expansion module 1
EPGM8 8 PGM output expansion module 1**
Wireless Devices
Device Description Max. Connectable Devices
EW1 Wireless 2 zone and 2 PGM output expansion module 16***
EW1B Battery-powered wireless 2 zone and 2 PGM output expansion module 16***
EWP1 Wireless motion detector 16***
EWD1 Wireless magnetic door contact 16***
EWD2 Wireless magnetic door contact/shock sensor/water sensor 16***
EWK1**** Wireless keyfob with 4 buttons 5***
EWK2**** Wireless keyfob with 4 buttons 5***
EWS1 Wireless indoor siren 16***
EWS2 Wireless outdoor siren 16***
EWS3 Wireless indoor siren 16***
EWF1 Wireless smoke detector 16***
* - A mixed combination of EKB2 and EKB3 keypads is supported. The combination can consist of up to 4 keypads in total.
** - Only 1 of these modules can be connected at a time if the module slots are implemented in ESIM264 unit.
*** - A mixed combination of wireless devices is supported. The combination can consist of up to 32 wireless devices in total.
**** - A mixed combination of EWK1 and EWK2 keyfobs is supported. The combination can consist of up to 5 keyfobs in total.
1.3. Default Parameters & Ways of Parameter Conguration
Main Settings
Parameter Default Value
Congurable by:
SMS EKB2 EKB3
Conguration
Tool
SMS & EKB2 Menu Language
Depends on rmware version according to user‘s lo-
cation
SMS Password 0000
User Password 1 1111
User Password 2... 30 N/A
Administrator Password 1470
Duress Password N/A
SGS Password N/A
User 1... 5 Phone Number N/A
Allow Control from Any Phone Number Disabled
Date & Time N/A
Exit Delay - Partition 1... 4 15 seconds
Info SMS Scheduler Frequency (days) – 1; Time - 11