20
20 EN
MANUAL ELDES ESIM264 V3.1
3. INSTALLATION
• The system can be installed in a metal or non-ammable cabinet only. For a convenient installation, ME1 metal cabinet is highly recom-
mended. When using a dierent metal cabinet, it is necessary to ground it.
• For the connection of 230V transformer, use 3x0.75 mm
2
1 thread double isolated cable. 230V power supply cables must not be
grouped with low voltage cable group.
• For the connection of auxiliary and BELL outputs, use 2x0.75 mm
2
1 thread unshielded cable of up to 100 meters length.
• For the connection of zone/PGM output connectors, use 0.50 mm
2
1 thread unshielded cable of up to 100 meters length.
System Installation in ME1 Metal Cabinet
1. ME1 metal cabinet components
Tamper switch
to AC main power line
to AC/DC terminals
of ESIM264 system
Phase
PE
Null
blue
brown
Fuse 1A
Transformer
(Primary voltage: 230V AC,
Secondary voltage: 17V 2,35A)
13
2. Insert the plastic standos into the appropriate mounting points and x the board of ESIM264 on the holders as indicated below.
mounting points
14
Vista de pagina 19