MANUAL ELDES ESIM264 V3.1
14.7. Bypassing and Activating Zones
ATTENTION: Zone bypassing and activation must be carried out without Conguration mode being activated by the EKB3 keypad.
Zone bypassing allows the user to deactivate a violated zone and arm the system without restoring the zone. If a bypassed zone is violated
or restored during exit/entry delay, or when then system is armed, it will be ignored. When a zone is bypassed, EKB3 keypad indi cator BYPS
will light ON and EKB2 keypad will display BYP message in the home screen view.
Bypass individual
violated zone
EKB2
Menu path:
OK → BYPASS → OK → BYPASS LIST 1... 3 → OK → Z1-zone-name... Z44-zone-name → OK →
BYPASS → OK K
Value: zone-name - up to 24 characters zone name.
EKB3
Press the [BYPS] key, enter zone number & user password:
BYPS nn uuuu #
Value: nn – zone number, range – [01... 44]; uuuu – 4-digit user password.
Example: BYPS091111#
Bypass all violated
zones
EKB2
Menu path:
OK → BYPASS → OK → BYP VIOLATED ZONES → OK
The zone will stay bypassed until the system is disarmed. Once the system is disarmed, the corresponding zone state will be indicated on
the keypads (see 31.1.1. EKB2 – LCD Keypad and 31.1.2. EKB3 – LED Keypad) and Info SMS text message (see 26. SYSTEM INFORMA-
TION. INFO SMS). Alternatively, the user can activate the bypassed zone by the following conguration methods.
Activate bypassed
zone
EKB2
Menu path:
OK → BYPASS → OK → BYPASS LIST 1...3 → OK → Z1-zone-name... Z44-zone-name → OK →
UNBYPASS → OK
Value: zone-name - up to 24 characters zone name.
EKB3
Press the [BYPS[ key, enter zone number & user password:
BYPS nn uuuu #
Value: nn – zone number, range – [01... 44]; uuuu – 4-digit user password.
Example: BYPS251111#
NOTE: Zones can only be bypassed and activated when the system is not armed.
14.8. Zone Names
Each zone has a name that can be customized by the user. Typically, the name species a device type connected to a determined zone
terminal, for Example: Kitchen doors opened. The zone names are used in SMS text messages that are sent to the user during alarm. the
By default, the zone names are: Z1 – Zone1, Z2 – Zone2, Z3 – Zone3, Z4 – Zone4 etc.
Set zone name
SMS
SMS text message content:
ssss_Znn:zone-name
Value: ssss – 4-digit SMS password; nn – zone number, range – [1... 44]; zone-name – up to
24 characters zone name.
Example: 1111_Z3:Door sensor triggered
Cong
Tool
This operation may be carried out from the PC using the ELDES Conguration Tool software.
View zone names
SMS
SMS text message content:
ssss_STATUS
Value: ssss – 4-digit SMS password.
Example: 1111_STATUS