12
12 EN
MANUAL ELDES ESIM264 V3.1
2. TECHNICAL SPECIFICATIONS
2.1. Electrical & Mechanical Characteristics
Electrical & Mechanical Characteristics
Main power supply 16-24V 50 Hz ~1.5A max / 18-24V 1,5A max
Current in standby without external sensors and keypad Up to 80mA
Recommended backup battery voltage, capacity 12V; 1,3-7 Ah
Recommended backup battery type Lead-Acid
Maximum battery charge current 900mA
Gsm modem frequency 850/900/1800/1900MHz
Cable type for GSM/GPRS antenna connection Shielded
Number of zones on-board 6 (ATZ mode: 12)
Nominal zone resistance 5,6k (ATZ Mode: 5,6k and 3,3k)
Number of PGM outputs on-board 4
On-board PGM output circuit
Maximum commuting on-board PGM output values 4 x Voltage – 30V; current – 500mA.
BELL: Siren output when activated Connected to COM
BELL: Maximum cable length for siren connection Up to 100 meters
BELL: Cable type for siren connection Unshielded
AUX: Auxiliary equipment power supply voltage 13,8V DC
BELL+AUX: Maximum accumulative current of auxiliary equipment & siren 1 A
AUX: Maximum cable length for auxiliary equipment connection Up to 100 meters
AUX: Cable type for auxiliary equipment connection Unshielded
BUZ: Maximum current of mini buzzer 150mA
BUZ: Power supply voltage of buzzer 5V DC
BUZ: Cable type for mini buzzer connection Unshielded
Supported temperature sensor model Maxim®/Dallas® DS18S20, DS18B20
Maximum supported number of temperature sensors 1
DATA: Maximum cable length for 1-Wire communication Up to 30 meters
DATA: Cable type for 1-Wire communication Unshielded
Supported ibutton key model Maxim®/Dallas® DS1990A
Maximum supported number of iButton keys 5
Maximum supported number of keypads 4 x EKB2 / EKB3
Y/G: Maximum cable length for RS485 communication Up to 100 meters
Y/G: Cable type for RS485 communication Unshielded
MIC: Maximum cable length for microphone connection Up to 2 meters
MIC: Cable type for microphone connection Unshielded
Wireless transmitter-receiver frequency 868 Mhz
Wireless communication range Up to 30m in premises; up to 150m in open areas
Maximum supported number of wireless devices 16
Event log size 500 events
Maximum supported number of zones 44
Maximum supported number of pgm outputs 44
Cable type for zone and pgm output connection Unshielded
Communications SMS, Voice calls, GPRS network, RS485, CSD
Supported protocols Ademco Contact ID, EGR100, Kronos, Cortex SMS
Dimensions 140x100x18mm
Operating temperature range -20...+55 °C
Humidity 0-90% RH @ 0... +40 °C (non-condensing)
1 R
OUT
Open Collector Output.
Output is pulled to COM
when turned ON.
Comentarios a estos manuales