7
7EN
MANUAL ELDES ESIM264 V3.1
Zones
Parameter Default Value
Congurable by:
SMS EKB2 EKB3
Conguration
Tool
Zone Name
Z1 - Zone 1; Z2 - Zone 2; Z3 - Zone 3; Z4 - Zone 4; Z5 -
Zone 5; Z6 - Zone 6
Entry Delay 15 seconds
On-Board Zone Delay 800 milliseconds
EPGM1 Zone Delay 800 milliseconds
On-board Z1 Zone Type Delay
On-board Z2... Z12 Zone Type Instant
Keypad Zone Type Instant
EPGM1 Zone Type Instant
Wireless Zone Type Depends on the connected wireless device
Virtual Zone Type Interior Follower
ATZ Mode Disabled
6-Zone Mode: Zone Connection Type Type 1
ATZ Mode: Zone Connection Type Type 4
On-board Zone Status Enabled
Keypad Zone Status Disabled
EPGM1 Zone Status Enabled
Wireless Zone Status Depends on the connected wireless device
Virtual Zone Status Disabled
Stay attribute for individual zone Disabled
Arm-Disarm by Zone N/A
Force atrribute for individual zone Disabled
Tamper Name
Tamper 1, Tamper 2, Tamper 3, Tamper 4, Tamper 5,
Tamper 6 etc.
Chime Enabled
PGM Outputs
Parameter Default Value
Congurable by:
SMS EKB2 EKB3
Conguration
Tool
PGM Output Name
C1 – Controll1, C2 – Controll2, C3 – Controll3, C4 – Con-
troll4 etc.
PGM Output Status Disabled
EPGM8 PGM Output Status Disabled
EPGM1 PGM Output Status Disabled
Wireless PGM Output Status Enabled
Wireless PGM Output Type Depends on the connected wireless device
PGM Output Control by Event 1... 16 Disabled
PGM Output Control by Event Manage-
ment
Scheduler 1... 16 Disabled
Turn ON/OFF PGM Output by Timer
Using Module EPGM8 Mode Disabled
Alarm Duration & Siren
Parameter Default Value
Congurable by:
SMS EKB2 EKB3
Conguration
Tool
Alarm Duration 1 minute
EWS2 LED Disabled
Bell Squawk Disabled
Activate Siren if Wireless Device is Lost Disabled
Comentarios a estos manuales