Typical Multi-Story or Split-Level House
Install a wireless smoke detector on the ceiling or wall inside each
bedroom and in the hallway outside each separate sleeping area. If
a bedroom area hallway is more than 9 meter long, install a wire-
less smoke detector at each end. Please install a wireless smoke
detector on the top of a rst-to-second oor stairwell.
LEGEND:
Minimum required smoke detector locations.
Recommended additional smoke detector locations
Bedroom Bedroom
Basement
Living
Room
Dining
Room
87
Incorrect EWF1 Placement
DO NOT place EWF1 in the following locations:
Near appliances or areas where normal combustion regularly occurs (kitchens, near furnaces, hot water heaters). Use specialized
wireless smoke detector with unwanted alarm control for this areas.
In areas with high humidity, like bathrooms or areas near dishwashers or washing machines. Install at least 3 meters away from these
areas.
Near air returns or heating and cooling supply vents. Install at least 1 meter away from these areas. The air could blow smoke away
from the detector, interrupting its alarm.
In rooms where temperatures may fall below 5
o
C or rise above 45
o
C.
In extremely dusty, dirty, or insect-infested areas where loose particles interfere with wireless smoke detector operation.
ATTENTION: Incorrect placement will result in a decrease of operational eectiveness.